HP 5300 Informacje Techniczne Strona 212

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 211
Power Over Ethernet (PoE) Operation
Planning and Implementing a PoE Configuration
“Warning” PoE Event-Log Messages
W < MM/DD/YY > < HH:MM:SS > chassis:
Message header, with severity, date, system time, and system
module type. For more information on Event Log operation,
including severity indicators, refer to
“Using the Event Log To
Identify Problem Sources” on page C-27".
Slot < slot-id > Ext Power Supply connected but not
responding.
The switch detects an external power supply on the module in the
indicated slot, but is not receiving power from the device.
Slot < slot-id > Ext Power Supply failure: < fault-type >
Failures:
Indicates an external power supply failure for the module in the
indicated slot, where < fault-type > is one of the following:
Over Current fault: The external power supply reported a fault
condition. Contact your HP ProCurve support representative.
Fan fault: A fan in an external power supply has failed.
Temperature fault: The operating temperature in an external
power supply has exceeded the normal operating range.
50V fault: The external power supply reported a fault
condition. Contact your HP ProCurve support representative.
12V fault: The external power supply reported a fault
condition. Contact your HP ProCurve support representative.
Slot < slot-id > POE usage has exceeded threshold of
< 1 - 99 > %
Indicates that POE usage in the indicated slot has exceeded the
configured threshold for the module, as specified by the last
execution of the power threshold or power slot < slot-id > threshold
command. (Note that the switch also generates an SNMP trap for
this event.)
Port < port-id > PD Denied power due to insufficient power
allocation.
There is insufficient power available to power the PD on the
indicated port and the port does not have sufficient PoE priority
to take power from another active PoE port.
11-24