When TURBOMODE is OFF and IPMBLOCKING is ON, the
Collector will block when it has time (waiting on CONS messages to
complete).
LATENCYCLOCKADJ hundredths
Initial Changed
Version Version Values Default Minimum Maximum Alter
2.603 0 -2147483647 2147483647 Yes
Client Server Extended Open Target
Defines a + or - differential to be used for calculating latency when the
source and target system clocks are not synchronized. The value is
subtracted from or added to the system clock before
LATENCYTHRESHOLD is evaluated. The valid values are -2147483647
through 2147483647. Input a minus sign (-) for a negative adjustment;
enter no sign for a positive adjustment. The default is 0.
LATENCYTHRESHOLD hundredths
Initial Changed
Version Version Values Default Minimum Maximum Alter
2.603 0 Off 0 2147483647 Yes
Client Server Extended Open Target
This sets the tolerance for latency monitoring. The value is added
following the processing of an audittrail event (i.e.,i.e., replicated to target),
the Consumer will add this to the associated event timestamp and
compare the result to current time to see if the threshold has been
exceeded. The default is 0 and means that Consumer latency monitoring
is off. Valid values are 0 to 2147483647.
LATENCYWARNRATE seconds
Initial Changed
Version Version Values Default Minimum Maximum Alter
2.603 0 0 2147483647 Yes
Client Server Extended Open Target
Sets the rate at which EMS messages are generated when the Consumer
has exceeded or recovers from exceeding the LATENCYTHRESHOLD.
Valid values are 0 to 2147483647. Note that you should choose a
reasonable value for this parameter for your operating environment. If the
value is set too low, it is quite possible that the EMS log will become
flooded with messages and impede HP Shadowbase performance. While
the default is 0; a value of 60 is recommended, when the parameter
LATENCYTHRESHOLD is set to a value greater than 0, to avoid flooding
EMS when a "behind" condition exists.