HP NonStop Shadowbase Command Definitions
Collector Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
71
Specifies the number of the CPU to be used as a backup for the Collector
process (which means the Collector process will run as a persistent
process). The CPU for the value entered must exist on the system. If the
AUD object AUTORESTART parameter is set to ON and the Collector
process fails due to a CPU failure, AUDMON will restart the Collector
process in the BACKUPCPU.
The default is no value assigned, meaning the Collector does not run as a
persistent process (if its primary CPU fails, it will not be restarted in
another CPU).
Note: That the BACKUPCPU can be altered at any time. If altered, the
new value will be used in the event a restart is performed.
CHKPTDELAY <hundredths of seconds>
Initial Changed
Version Version Values Default Minimum Maximum Alter
4.000B 500 0 32767 Yes
This defines the minimum time duration to wait between updates to the
restart file. It is specified in 1/100
th
second units. The default is 500 (5
seconds). The minimum value is 0 and the maximum is 32767. When set
to 0, the COLL will update the restart file every 262,144 bytes of master
audit trail data read (this is the old HP Shadowbase algorithm).
CHKPTDELAY can be altered at any time. Note that CHKPTDELAY
should typically be set less than CHKPTTIME which is the maximum time
duration to wait before the restart file is updated. Also, note that
CHKPTDELAY is not considered during the rollover from one audit trail to
the next audit trail. In that case, the restart file is updated without a delay.
CHKPTTIME <number of seconds>
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.960C 300 0 disable 32767 Yes
This defines the timer value for the Collector to wait before refreshing the
RESTARTFILE restart position. The valid range is 0 through 32767
seconds. The default is 300 (5 minutes). .
Note: Lag checking is disabled when CHKPTTIME is set to 0.
CHKPTWARNRATE <number of seconds>
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.960C 4.090 900 0 2147483647 Yes