Display Messages
C-26 HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages continued
Message Type Description Action
108 VOLUME #<n>
STATE MISSING
DRIVES
Error The configured volume is
unusable because it is
missing too many of the
physical drives that
constitute the volume.
The controller will disable
this volume.
1. Power down the
MSA500 system.
2. Power down all
attached storage
enclosures.
3. Remove and reinstall
all SCSI drives, and be
sure that they seat fully
in their bays.
4. Check for proper
connections on the
cables between the
MSA500 system and
any attached storage
enclosures.
5. Power up the attached
storage enclosures.
6. Power up the MSA500
system.
If this action does not solve
the problem, contact HP
support.
continued