Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide C-41
Table C-1: Display Messages continued
Message Type Description Action
501 PCI
SUBSYSTEM
HARDWARE
FAILURE
Error The array controller PCI
subsystem encountered
a critical error during the
power up sequence.
1. Remove the failed array
controller.
2. Wait 10 seconds.
3. Reinstall the array
controller, and be sure
that it seats fully in the
chassis.
If this action does not solve
the problem, contact HP
support.
502 PCI BRIDGE
ASIC SELF TEST
FAILURE
Error The array controller PCI
bridge ASIC has
encountered a critical
error during the power up
sequence.
1. Remove the failed array
controller.
2. Wait 10 seconds.
3. Reinstall the array
controller, and be sure
that it seats fully in the
chassis.
If this action does not solve
the problem, contact HP
support.
513 UNCORRECTED
ECC MEMORY
ERROR SEEN
Error The array controller has
detected an
uncorrectable error in the
ECC memory on the
memory cache board.
Remove the failed array
controller and replace the
cache module DIMM.
518 <name>
CONNECTION LOST
Error The named connection
has been lost.
Check SCSI connections to
the server.
Also, the controller may
have a failed SCSI
controller chip.
519 <name>
CONNECTION
RESTORED
Informational The named connection
has been restored.