Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide C-31
Table C-1: Display Messages continued
Message Type Description Action
125 ACCESS
CONTROL
CONFLICT
DETECTED
Error A set of volumes have
been migrated from one
array controller to a
different array controller
that already contains
configured volumes. The
migrated volumes have
access controls defined
for them that conflict with
the existing
configuration. The
access controls have
been modified to allow
the migration to proceed.
Run ACU to check the new
access controls and modify
them if needed.
126 ACCESS
CONTROL
RESOURCES
EXCEEDED
Error A set of volumes have
been migrated from one
array controller to a
different array controller
that already has
configured volumes on it.
The migrated volumes
have access controls
defined for them that
conflict with the existing
configuration. The
access controls have
been modified so as to
allow the migration to
proceed.
Run ACU to check the new
access controls and modify
them if needed.
201 ARRAY
CONTROLLER
TEMPERATURE OK
Informational The controller
temperature is within the
normal operating range.
Message 201 follows
messages 202 and 203
when the temperature
problem no longer exists.