Configuration and Utilities
4-12 HP StorageWorks Modular Smart Array 500 System User Guide
Drive Rebuild, Expand Priority, and Accelerator Ratio
To set the drive rebuild priority, expand priority, or accelerator ratio for a controller:
1. Go to the Main Configuration View screen.
2. Highlight the controller.
3. Select the Controller Settings option listed below Controller Options. The
Controller Settings screen appears.
Drive Rebuild
Drive rebuild occurs after a physical drive fails and is replaced. Only logical drives
configured for fault tolerance (RAID 1, RAID 5, ADG) on the array with the failed
physical drive will rebuild.