
Display Messages
C-38 HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages continued
Message Type Description Action
406 STORAGE BOX
#<n> OVERHEATING
Error The temperature sensor
in the storage enclosure
indicates that the
enclosure is exceeding
the normal operating
range.
1. Power down the
MSA500 system as
soon as possible to
avoid hardware failure.
2. Be sure that all
MSA500 system fans
are operating.
3. Replace any failed
fans.
4. Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
407 STORAGE BOX
#<n> OVERHEATED
Error The temperature sensor
in the storage enclosure
indicates that the
enclosure exceeded the
safe operating range.
1. Power down the
MSA500 system as
soon as possible to
avoid hardware failure.
2. Be sure that all
MSA500 system fans
are operating.
3. Replace any failed
fans.
4. Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
continued
Komentarze do niniejszej Instrukcji