Hp StorageWorks 500 Modular Smart Array Instrukcja Użytkownika Strona 96

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 95
Display Messages
C-4 HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages continued
Message Type Description Action
31 I2C WRITE
FAILURE <I2C device
name>
Error Read access has failed
to an internal device on
an I2C hardware bus.
Certain I2C devices are
considered critical and
will result in a failure of
the array controller while
others may result in
some loss of functionality
(such as lost display
messages).
Replace the device.
If this action does not solve
the problem, contact HP
support.
32 CHASSIS NVRAM
CONTENTS
CORRUPTED
Error NVRAM is corrupt. The
system cannot continue
to operate.
Contact HP support.
40 BEGIN
REDUNDANCY
SUPPORT
Informational The array controllers are
attempting to enter
redundant mode.
41 REDUNDANCY
ACTIVE ACTIVE
CONTROLLER
Informational The array controllers are
now in redundant mode
and this array controller
is active with enabled
access to the configured
volumes on the MSA500
system.
42 REDUNDANCY
ACTIVE STANDBY
CONTROLLER
Informational The array controllers are
now in redundant mode
and this array controller
is in standby, available
to be made active if the
current active array
controller fails, assuming
proper cabling and
installation.
continued
Przeglądanie stron 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 156 157

Komentarze do niniejszej Instrukcji

Brak uwag