Hp StorageWorks 500 Modular Smart Array Instrukcja Użytkownika Strona 129

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 128
Display Messages
HP StorageWorks Modular Smart Array 500 System User Guide C-37
Table C-1: Display Messages continued
Message Type Description Action
402 STORAGE BOX
#<n> FAN
DEGRADED
Error The specified storage
enclosure indicates that
one of its fans is not
operating at full
efficiency. The fan may
eventually fail.
1. Be sure that all
MSA500 system fans
are operating.
2. Replace any failed
fans.
If this action does not solve
the problem, contact HP
support.
403 STORAGE BOX
#<n> FAN HOT
INSERTED
Informational The specified storage
enclosure indicates that
a fan was added.
404 STORAGE BOX
#<n> FAN HOT
REMOVED
Informational The specified storage
enclosure indicates that
a fan was removed.
405 STORAGE BOX
#<n>
TEMPERATURE OK
Informational The temperature sensor
in the storage enclosure
indicates that the
temperature is in the
normal operating range.
continued
Przeglądanie stron 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 156 157

Komentarze do niniejszej Instrukcji

Brak uwag