HP D2D2502i Podręcznik Użytkownika Strona 18

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 178
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 17
alerts show
Description of Command Function
Lists all events with a severity of critical” or error.
NOTE: The command logs show events can also be used to show all events or filtered
events, not just critical or error events. See “logs show events (page 53).
Command Syntax
alerts show [verbose] [numofevents <number>]
Command Authority
Operator, Administrator
Command Object Requirements
Not applicable no objects exist within this command.
Command Parameter Requirements
verbose When this parameter is included in the command entry a detailed output is provided.
numofevents When this parameter is use a integer must follow the numofevents text. This
is the maximum number of events which will be listed in the output, starting with the most
recent events.
Requirements for Command Execution
The command entry must conform to the command syntax.
Successful Command Output
Upon successful completion of the command, a list of the most recent events up to 20 events is
displayed starting with the most recent event. The output includes the event time, level, and
description.
If the verbose parameter is included, a detailed list of information for each event is output. If the
numofevents parameter is included, the maximum number of events displayed is defined by the
interger provided with this parameter. The list of events starts with the most recent event.
Command Operation during Abnormal Conditions
If the command does not conform to the required syntax, the following is displayed:
Command Failed - the command does not conform to the required syntax,
SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this
section.
Examples
> alerts show
EVENT ID TIMESTAMP LEVEL TEXT
-------- --------------- ----- -------------------------------------------------------------------------------
580 Jul 21 16:22:50 ALERT HBA link 50.06.05.b0.02.56.45.00 on host d2dd48564785fd8_node_1 status is
stale
> alerts show verbose
EVENT ID TIMESTAMP LEVEL TEXT
FILESYSTEM HOST USER NAME OPERATION SEGMENT NUMBER PV NUMBER NIC HBA
RELATED EVENT
-------- --------------- ----- -------------------------------------------------------------------------------
---------- ---------------------- --------- --------- -------------- --------- --- -----------------------
-------------
580 Jul 21 16:22:50 ALERT HBA link 50.06.05.b0.02.56.45.00 on host d2dd48564785fd8_node_1 status is
stale d2dd48564785fd8_node_1
50.06.05.b0.02.56.45.00 0
NOTE: The example output is in a small font to fit on this specification page. As a CLI output,
the character string will simply wrap at the end of a terminal line.
18 Alphabetical List of Commands and Details
Przeglądanie stron 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 177 178

Komentarze do niniejszej Instrukcji

Brak uwag