HP D2D2502i Podręcznik Użytkownika Strona 53

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 178
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 52
logs show events
Description of Command Function
Lists all the items in the event log. If a severity parameter is included in the command entry, only
events at or greater than the defined severity are displayed.
Command Syntax
logs show events [severity {alert|warni|info}] [numofevents <number>]
(default = 20)
Command Authority
Operator, Administrator
Command Object Requirements
Not applicable no objects exist within this command.
Command Parameter Requirements
severity This is an optional parameter which filters which events are displayed. The parameter
appears after “logs show” in the command entry. It consists of the text severity” followed by one
of these values:
alerts
warn
info
Requirements for Command Execution
The command entry must conform to the command syntax.
Successful Command Output
Upon successful completion of the command, the output is displayed as in the example below.
Command Operation during Abnormal Conditions
If the command does not conform to the required syntax, the following is displayed:
Command Failed - the command does not conform to the required syntax,
SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this
section.
Example
> logs show events
EVENT ID TIMESTAMP LEVEL TEXT
FILESYSTEM HOST USER NAME OPERATION
SEGMENT NUMBER PV NUMBER NIC HBA RELATED EVENT
-------- --------------- -----
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
---------- ---------------------- --------- --------- -------------- --------- -------
----------------------- -------------
644 Aug 3 19:00:41 INFO Nic bond1:3 on host d2d78e7d1e6928e_node_1 inactive
d2d78e7d1e6928e_node_1
bond1:3 0
643 Aug 3 18:59:55 INFO Nic bond1:1 on host d2d78e7d1e6928e_node_2 up
d2d78e7d1e6928e_node_2
bond1:1 0
642 Aug 3 18:59:46 INFO Server d2d78e7d1e6928e_node_2 failed back
d2d78e7d1e6928e_node_2
0
640 Aug 3 18:59:40 WARN Server d2d78e7d1e6928e_node_2 in failback
d2d78e7d1e6928e_node_2
0
639 Aug 3 18:59:40 INFO Command from Local Host, user root: Failover for server d2d78e7d1e6928e_node_2.
d2d78e7d1e6928e_node_2
0
638 Aug 3 18:58:54 INFO Nic bond1:1 on host d2d78e7d1e6928e_node_2 inactive
d2d78e7d1e6928e_node_2
logs show events 53