OfficeConnect Gigabit VPN Firewall User’s Manual Chapter 3. Quick Start Guide
11
Mechanical Loading - Mounting of the equipment in the rack
should be such that a hazardous condition is not achieved due to
uneven mechanical loading.
Circuit Overloading - Consideration should be given to the
connection of the equipment to the supply circuit and the effect
that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing
this concern.
Reliable Earthing - Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to
supply connections other than direct connections to the branch
circuit (e.g. use of power strips).
Follow these instructions to install OfficeConnect Gigabit VPN Firewall to your
19-inch rack:
1. Place the unit the right way up on a hard, flat surface with the front
facing towards you.
2. Locate a mounting bracket over the mounting holes on one side of
the unit, as shown in Figure 3.2 below.
3. Insert the two screws and fully tighten with a suitable screwdriver.
4. Repeat the two previous steps for the other side of the unit.
5. Insert the unit into the 19-inch rack and secure with suitable screws
(not provided).
6. Reconnect all cables.
Figure 3.2 Assembling the rack mount kit
Figure 3.3 Rack Mounting
3.3 Part 3 — Configuring Your Computers
Part 3 of the Quick Start Guide provides instructions for configuring the Internet
settings on your computers to work with the OfficeConnect Gigabit VPN Firewall.