NOTE: When the HP Jetdirect rmware is upgraded, a device might be left in a short stack condition
if the device is disconnected during the upgrade process or a fatal error occurs. HP Web Jetadmin
detects this error condition and tries the upgrade again to make sure that the device is not left in an
incomplete upgrade state.
Printer Firmware—Displays detailed information about the device rmware on the selected devices.
The Printer Firmware - Severity column can be used to verify that the device rmware is up-to-date. A
green icon indicates that the latest version of the device rmware in the Firmware Repository is
installed on the device. A yellow icon indicates that a newer version of the device rmware is available
in the Firmware Repository. The Up-to-date icon is displayed in this column if the rmware version on
the device is newer than the rmware versions that are available in the Firmware Repository or if the
rmware version on the device is the same as the latest rmware version that is available in the
Firmware Repository.
By default, HP Web Jetadmin checks for newer rmware versions in the HP Web Jetadmin Firmware
Repository. Instead of checking all rmware les in the HP Web Jetadmin rmware repository, it can
validate if newer qualied images are available in the HP Web Jetadmin repository by changing the
value for ConsiderQualiedFirmwareAsLatest in the FirmwareUpgrade.cong.xml to True. If this
setting is not available in the FirmwareUpgrade.cong.xml le, then add the full section:
<property name="ConsiderQualifiedFirmwareAsLatest">
<type>HP.Imaging.Wjp.Sdk.Core.Framework.ConfigurationItemString
</type>
<value>True</value>
</property>
After changing the value in the xml le, restart HP Web Jetadmin. If the value for
ConsiderQualiedFirmwareAsLatest in the FirmwareUpgrade.cong.xml is set to True,
HP Web Jetadmin will only consider the qualied rmware image as the latest image, even if there is
a non-qualied image with a later rmware datecode and version available in the HP Web Jetadmin
repository. If none of the rmware images are set as qualied, then it will always show the existing
device rmware as up-to-date.
By default, the FirmwareUpgrade.cong.xml can be found in:
C:\Windows\ServiceProles\NetworkService\AppData\Local\HP Inc\HPWebJetadmin\WjaService
\cong
The Printer Firmware - Available in WJA Repository column displays the number of device rmware
les in the Firmware Repository that are available to install or reinstall on the device. This number
includes the current device rmware le and all of the new rmware les in the Firmware Repository
that can be installed or reinstalled on the device. The Up-to-date icon is displayed in this column if the
rmware version on the device is newer than the rmware versions that are available in the Firmware
Repository.
Jetdirect Firmware—Displays detailed information about the HP Jetdirect rmware on the selected
devices.
The Jetdirect Firmware - Severity column can be used to verify that the HP Jetdirect rmware is up-
to-date. A green icon indicates that the latest version of the HP Jetdirect rmware in the Firmware
Repository is installed on the device. A yellow icon indicates that a newer version of the HP Jetdirect
rmware is available in the Firmware Repository. The Up-to-date icon is displayed in this column if the
rmware version on the device is newer than the rmware versions that are available in the Firmware
Repository or if the rmware version on the device is the same as the latest rmware version that is
available in the Firmware Repository.
The Jetdirect Firmware - Available column displays the number of HP Jetdirect rmware les in the
Firmware Repository that are available to install or reinstall on the device. This number includes the